Siemens SINUMERIK 840D sl Series Diagnostics Manual page 30

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
• LINK_BAUDRATE_SWITCH,
• SYSCLOCK_CYCLE_TIME
The values of these machine data must be the same on all NCUs.
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
The machine data required for the link module configuration must be the same on all
NCUs in the cluster.
Program Con-
Switch control OFF - ON.
tinuation:
4014
Axis %1 defined several times in %2
Parameters:
%1 = String: MD identifier
%2 = String: Check and, if necessary, correct the following machine data with reference
to the data sheet:
Definitions:
An axis was assigned several times.
The axis can be a:
• Machine axis
• Link axis
• Axis in a container location
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Define a correct, unique axis assignment.
Program Con-
Switch control OFF - ON.
tinuation:
4016
Axis %1 already used by NCU %2
Parameters:
%1 = Machine axis index
%2 = NCU number
Definitions:
An attempt was made to apply setpoints to one axis from several NCUs. Only occurs with
the NCU link system
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Define a correct, unique axis assignment.
Program Con-
Switch control OFF - ON.
tinuation:
4017
Axis container %1, location %2 already used by NCU %3
Parameters:
%1 = Axis container number
2-30
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005