08/2005
Reactions:
- Alarm display.
Remedy:
Close the simulation and make the selection again.
The alarm disappears automatically as soon as a program is edited or simulated in the
program area.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
120310
The selection is not possible. Please wait for the pending action or terminate it,
then repeat the selection.
Definitions:
In the program area, programs are currently being copied, loaded or unloaded.
A simultaneous editing is not possible.
Reactions:
- Alarm display.
Remedy:
Wait until the action is completed or terminate the action via the softkey "Cancel" and then
repeat the selection.
The alarm disappears automatically as soon as a program is edited or simulated in the
program area.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
129900
Data of passive drives are not backed up!
Definitions:
This indicates that passive drives are not backed up as well when an upgrade is made.
Reactions:
- Alarm display.
Remedy:
If the drive shall be backed up as well, it must be enabled. If the note shall not be dis-
played again, set the drive to "0" in machine data 30240 ENC_TYPE and 30130
CTRLOUT_TYPE.
Program Con-
Internal
tinuation:
129901
Time determination is being initialized. Please wait...
Definitions:
This indicates that the time determination is being initialized and that the operator shall
not yet press NC Start or execute other operator actions.
Reactions:
- Alarm display.
Remedy:
Not necessary. After completion of the initialization, the dialog box will be faded out again
automatically.
Program Con-
Internal
tinuation:
129902
Recorded data are being processed. Please wait...
Definitions:
This indicates that data recorded by time determination are currently processed and that
the operator shall not yet press NC Start or execute other operating actions.
Reactions:
- Alarm display.
Remedy:
Not necessary. After completion of the initialization, the dialog box will be faded out again
automatically.
Program Con-
Internal
tinuation:
129903
Time determination is active.
Definitions:
This indicates that time determination is enabled and that the user can press NC Start.
Reactions:
- Alarm display.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-613