08/2005
- Alarm display.
Remedy:
Error code = 1 or 4 : Remove all block numbers from cc_resu_ini.spf and
cc_resu_end.spf and their subroutines.
Error code = 2 : Assign a higher value to machine date
$MN_MM_DRAM_FILE_MEM_SIZE.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75605
Channel %1 RESU: internal error, error code %2
Parameters:
%1 = Channel number
%2 = Error code
Definitions:
With this alarm, RESU-internal error states are displayed which, together with the trans-
ferred error number, provide information on the error cause and error location.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
If this error occurs, please contact us on the SINUMERIK Hotline of the SIEMENS AG,
specifying the error number.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75606
Channel %1 RESU: retraceable contour was shortened
Parameters:
%1 = Channel number
Definitions:
The block search buffer is full. Therefore the retraceable contour had to be shortened.
Reactions:
- Alarm display.
Remedy:
This alarm has no effect on the current machining. If the alarm continues to occur fre-
quently, the reason should be eliminated: adjust machine data
$MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM and
$MC_MM_NUM_CC_HEAP_MEM.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
75607
Channel %1 RESU: resynchronisation not possible
Parameters:
%1 = Channel number
Definitions:
The block search triggered by the compile cycle has been terminated with an error. It can
have the following cause: The control is not in the correct operating mode, e.g. in JOG_
AUTO instead of in AUTO.
Reactions:
- Interface signals are set.
- Alarm display.
Remedy:
Switch the control to the AUTO operating mode and restart resynchronisation.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
75608
Channel %1 RESU: NC memory limit reached, RAM type %2
Definitions:
A memory limit was reached on writing to file cc_resu.mpf. The possible area for return
traveling is shortened.
RAM type = 1: File cc_resu.mpf is created in the buffer memory (SRAM). The buffer mem-
ory is therefore full. If the buffer memory is used and if alarm 75608 with RAM type 1 is
output, system alarm 6500 will be output simultaneously.
RAM type = 2: The memory limit was reached on creating file cc_resu.mpf in the dynamic
memory (DRAM part program memory).
Reactions:
- Alarm display.