Siemens SINUMERIK 840D sl Series Diagnostics Manual page 446

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
- Interpreter stop
Remedy:
Check parameters _LENG and _WID.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61119
Channel %1 Block %2: Nominal or core diameter programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The nominal or core diameter was incorrectly programmed. Alarm triggered by following
cycles: CYCLE70, E_MI_TR, F_MI_TR.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Check thread geometry.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61120
Channel %1 Block %2: Thread type inside / outside not defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The thread type (internal/external) was not defined. Alarm triggered by following cycles:
CYCLE70.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
The internal/external thread type must be entered.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61121
Channel %1 Block %2: Number of teeth per cutting edge is missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No value was entered for the number of teeth per cutting edge. Alarm triggered by follow-
ing cycles: CYCLE70.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Enter the number of teeth/cutting edges for the active tool into the tool list.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61122
Channel %1 Block %2: Safety distance incorrectly defined in plane
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The safety clearance is negative or zero. This is not allowed.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
2-446
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents