Siemens SINUMERIK 840D sl Series Diagnostics Manual page 102

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
• %2 = 30XX => different contents in MD 30550 slave axis and master axis
• %2 = 40XX => different channel or NCU assignment of the gantry axes
• %2 = 50XX => no slave axis declared in this channel
• 2% = 60XX => different channel assignment of the master axis
• %2 = 10000 => error: slave axis is geometry axis
• %2 = 11000 => error: competing positioning axis as slave axis
• %2 = 12000 => error: compile cycle axis as slave axis
• %2 = 13000 => error: gantry axis is spindle
• %2 = 14000 => error: gantry axis is Hirth geared
e.g. error code 1001 = no master axis declared, gantry unit 1.
Reactions:
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Correct the machine data:
MD 37100 GANTRY_AXIS_TYPE
0: No gantry axis
1: Master axis grouping 1
11: Slave axis grouping 1
2: Master axis grouping 2
12: Slave axis grouping 2
3: Master axis grouping 3
13: Slave axis grouping 3
Program Con-
Switch control OFF - ON.
tinuation:
10652
Channel %1 axis %2 gantry warning threshold exceeded
Parameters:
%1 = Channel number
%2 = Axis
Definitions:
The gantry following axis has exceeded the warning limit specified in MD 37110
GANTRY_POS_TOL_WARNING.
Reactions:
- Alarm display.
Remedy:
Please inform the authorized personnel/service department.
1. Check axis (uneven mechanical movement?)
2. MD not set correctly (MD 37110 GANTRY_POS_TOL_WARNING). Changes to this
MD take effect after a RESET.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
10653
Channel %1 axis %2 gantry error threshold exceeded
Parameters:
%1 = Channel number
%2 = Axis
Definitions:
The gantry following axis has exceeded the error limit (actual value tolerance) specified in
MD 37120 GANTRY_POS_TOL_ERROR.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
2-102
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents