Siemens SINUMERIK 840D sl Series Diagnostics Manual page 514

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE105.
The maximum number of characters per line has been limited to 200 characters per line.
Remedy:
--
62311
Channel %1 block %2: The max. number of characters per line _PROTFORM[1] is
adjusted
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycles: CYCLE105
Max. number of characters per line _PROTFORM[1] has been adjusted.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62312
Channel %1 block %2: probe is not perpendicular to plane!
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62900
Channel %1 block %2: Incorrect source file
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62901
Channel %1 block %2: Source file not available
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reactions:
- Interpreter stop
- NC Start disable in this channel.
2-514
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition