• 47 Actual position - SG[1] $MA_SAFE_VELO_LIMIT[1].
• 48 Actual position + SG[2] $MA_SAFE_VELO_LIMIT[2].
• 49 Actual position - SG[2] $MA_SAFE_VELO_LIMIT[2].
• 50 Actual position + SG[3] $MA_SAFE_VELO_LIMIT[3].
• 51 Actual position - SG[3] $MA_SAFE_VELO_LIMIT[3].
• 52 Standstill position + tolerance $MA_SAFE_STANDSTILL_TOL.
• 53 Standstill position - tolerance $MA_SAFE_STANDSTILL_TOL.
• 54 Actual postion + n_x + tolerance $MA_SAFE_VELO_X + $MA_SAFE_POS_TOL.
• 55 Actual postion + n_x $MA_SAFE_VELO_X.
• 56 Actual postion - n_x $MA_SAFE_VELO_X.
• 57 Actual postion - n_x - tolerance $MA_SAFE_VELO_X - $MA_SAFE_POS_TOL
• 58 Active external standstill request.
• 59 SG override factor 1 $MA_SAFE_VELO_OVR_FACTOR[0].
• 60 SG override factor 2 $MA_SAFE_VELO_OVR_FACTOR[1].
• 61 SG override factor 3 $MA_SAFE_VELO_OVR_FACTOR[2].
• 62 SG override factor 4 $MA_SAFE_VELO_OVR_FACTOR[3].
• 63 SG override factor 5 $MA_SAFE_VELO_OVR_FACTOR[4].
• 64 SG override factor 6 $MA_SAFE_VELO_OVR_FACTOR[5].
• 65 SG override factor 7 $MA_SAFE_VELO_OVR_FACTOR[6].
• 66 SG override factor 8 $MA_SAFE_VELO_OVR_FACTOR[7].
• 67 SG override factor 9 $MA_SAFE_VELO_OVR_FACTOR[8].
• 68 SG override factor 10 $MA_SAFE_VELO_OVR_FACTOR[9].
• 69 SG override factor 11 $MA_SAFE_VELO_OVR_FACTOR[10].
• 70 SG override factor 12 $MA_SAFE_VELO_OVR_FACTOR[11].
• 71 SG override factor 13 $MA_SAFE_VELO_OVR_FACTOR[12].
• 72 SG override factor 14 $MA_SAFE_VELO_OVR_FACTOR[13].
• 73 SG override factor 15 $MA_SAFE_VELO_OVR_FACTOR[14].
• 74 SG override factor 16 $MA_SAFE_VELO_OVR_FACTOR[15].
• 75 Velocity limit n_x $MA_SAFE_VELO_X.
• 76 Stop reaction SG1 $MA_SAFE_VELO_STOP_REACTION[0].
• 77 Stop reaction SG2 $MA_SAFE_VELO_STOP_REACTION[1].
• 78 Stop reaction SG3 $MA_SAFE_VELO_STOP_REACTION[2].
• 79 Stop reaction SG4 $MA_SAFE_VELO_STOP_REACTION[3].
• 80 Modulo value for safe cam $MA_SAFE_MODULO_RANGE.
• 81 Velocity tolerance for safe deceleration ramp $MA_SAFE_STOP_VELO_TOL.
• 82 SG override factor SGE 0...15 = active SGE position. -1 = SG override inactive (nei-
ther SG2 nor SG4 active, or function not activated in $MA_SAFE_FUNCTION_ENABLE).
• 83 Acceptance test time different $MA_SAFE_ACCEPTANCE_TST_TIMEOUT.
• 84 Delay time Stop F -> Stop B $MA_SAFE_STOP_SWITCH_TIME_F.
• 85 Delay time pulse disable bus fail $MN_SAFE_PULSE_DIS_TIME_BUSFAIL.
• 86 Single encoder system $MA_SAFE_SINGLE_ENC.
• 87 Encoder assignment $MA_SAFE_ENC_INPUT_NR.
• 88 Cam enable $MA_SAFE_CAM_ENABLE.
• 89 Encoder limit frequency $MA_SAFE_ENC_FREQ_LIMIT (Performance_2 only).
• 90 Cam SGA outside $MA_SAFE_CAM_TOL different
• 1000 Control timer expired: If one channel informs another of an SGE change, this con-
trol timer is used to check whether the update timer in the other channel has expired.
• 1001 (only assigned on drive, see alarm 300911)