List of Action Numbers
No. 12
Explanation
Perform a user interrupt at the end of the block (VDI signal: ASUB interface, digital-ana-
log interface).
Not allowed if
See 10
Remedy
-
No. 13
Explanation
Perform a rapid retraction (VDI signal: Digital-analog interface and ASUB interface, for
further actions see 10, 11, 12, 85, 86).
Not allowed if
-
Remedy
-
No. 14
Explanation
Move tool - only with tool management (PI command).
Not allowed if
-
Remedy
-
No. 15
Explanation
Perform deletion of distance-to-go or axis synchronization (VDI signal: deletion of dis-
tance-to-go or follow-up mode) (follow-up mode: e.g. on activation of axis motion).
Not allowed if
1. nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy
Abort program
No. 16
Explanation
Abort repetition of subroutine (VDI signal: Delete number of subroutine repetitions).
Not allowed if
1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy
Abort program