Siemens SINUMERIK 840D sl Series Diagnostics Manual page 617

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Remedy:
Ensure that all channels configured in the workpiece for time measurement are in the
"Reset" state.
129942
Not all involved channels are in AUTO.
Definitions:
At least one channel/mode group configured in the workpiece for time measurement is
not in the "AUTO" mode.
Remedy:
Ensure that all channels/mode groups configured in the workpiece for time measurement
are in the "AUTO" state.
129943
%1: Invalid configuration of $AN_TIMER.
Parameters:
%1 = NCU name
Definitions:
Setting AN_TIMER_No of section [DAT] in ITS.INI is incompatible with the setting in
machine data 18710 $MN_MM_NUM_AN_TIMER.
Remedy:
The value in general machine data 18710 $MN_MM_NUM_AN_TIMER must be at least
"1".
The value set for AN_TIMER_No of section [DAT] in ITS.INI must be higher than "0" and
smaller than or equal to the value of general machine data 18710
$MN_MM_NUM_AN_TIMER.
The following rule applies:
0 < AN_TIMER_Nr <= $MN_MM_NUM_AN_TIMER
129944
%1: $AN_TIMER[%2] not running.
Parameters:
%1 = NCU name
%2 = Index of system variable $AN_TIMER used.
Definitions:
The $AN_TIMER[AN_TIMER_No] configured with setting AN_TIMER_Nr of section [DAT]
in ITS.INI has not been started.
Remedy:
Ensure that system variable $AN_TIMER[AN_TIMER_No] with value "0" is initialized and
started on NCU ramp-up; for example, with AN_TIMER_No = 1 the system variable must
be initialized with NC instruction $AN_TIMER[1] = 0.
129945
%1: The current NCK version (%2) is too old for this type of time measuring.
Parameters:
%1 = NCU name
%2 = NCK software version of NCU %1.
Definitions:
Measuring method "1" configured with setting MeasureMode of section [DAT] in ITS.INI
cannot be used, as the current NCK version is too old.
Remedy:
Either upgrade NCK software to at least 511300 or select measuring method "0".
129946
General error. See entry in log file ITSx.LOG.
Definitions:
A general error has occured that is specified in detail in log file "ITSx.LOG".
The files are stored in sub-directory "SEditor" of the "TMP" directory in HMI Advanced.
Remedy:
Follow the instructions in log file "ITSx.LOG" or contact the Siemens hotline.
142000
Operator at the machine is waiting for support via remote diagnostics! %1 %2 %3
%4
Parameters:
%1 = IP address for existing Internet connection via modem
Definitions:
Will be triggered in "User Controlled" mode, if user uses "Request Support" function.
Reactions:
- Alarm display.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-617