%2 = Axis container location
%3 = NCU number
Definitions:
A multiple reference to the axis container location has been made via the logical axis
table (machine data: MN_AXCONF_LOGIC_MACHAX_TAB). With the NCU link, the mul-
tiple reference may also have been made by another NCU in the NCU group.
Example: Container1 location1 was referenced twice incorrectly
• MN_AXCONF_LOGIC_MACHAX_TAB[0] = CT1_SL1
• MN_AXCONF_LOGIC_MACHAX_TAB[6] = CT1_SL1
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct and complete the container location assignments. Check the machine data for the
logical axis assignment table (MN_AXCONF_LOGIC_MACHAX_TAB)
Program Con-
Switch control OFF - ON.
tinuation:
4018
Axis container %1, location %2 not used by any channel
Parameters:
%1 = Axis container number
%2 = Axis container location
Definitions:
The container location is not referenced by any channel.
Reactions:
- NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct and complete the container location assignments. Check machine data
MC_AXCONF_MACHAX_USED and MN_AXCONF_LOGIC_MACHAX_TAB.
Program Con-
Switch control OFF - ON.
tinuation:
4019
Axis container %1 advance not allowed with current status of NCU %2
Parameters:
%1 = NCU number
%2 = Axis container number
Definitions:
This error only occurs with direct advancing of the container. With direct container
advancing, only one channel is allowed to activate the NC language command for
advancing the container. In order to ensure this, the other channels must have the reset
status and the axes must be stationary.
With NCU link, the above condition applies to all channels of the NCU group.
Error parameters:
• 1 : NC Ready missing
• 16: At least one other channel is active
• 35: AXCT axis is active following axis/spindle
• 36: AXCT axis is active leading axis
• 39: Axis/spindle disable active
• 40: Overlaid motion active for AXCT axis
• 41: Axis replacement active for AXCT axis
• 42: Interpolator active for one axis container axis
• 46: Rotating spindle with different Ipo cycle of NCUs
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition