Overview of Alarms
Disconnect one of the two absolute encoders: Replace the motor measuring system by
using another motor or use another encoder for direct measuring system.
Correct the corresponding entries in MD 1011: $MD_ACTUAL_VALUE_CONFIG (actual
value sensing configuration IM) or MD 1030: $MD_ACTUAL_VALUE_CONFIG_DIRECT
(actual value sensing configuration DM).
Program Con-
Switch control OFF - ON.
tinuation:
300738
Axis %1 drive %2 module number for measuring system not possible
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The NC has assigned the direct measuring system to an axis which doesn't have a motor
measuring system. This error can only occur with the 810D!
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Check the configuration of
the direct measuring system. See NC-MD 30220: $MA_ENC_MODULE_NR and NC-MD
30230: $MA_ENC_INPUT_NR.
Program Con-
Switch control OFF - ON.
tinuation:
300739
Axis %1 drive %2 measuring system already used as motor measuring system
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The NC has assigned the direct measuring system to a measuring system output which is
already used by another motor measuring system. This error can only occur with the
810D!
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Check the configuration of
the direct measuring system. See NC-MD 30220: $MA_ENC_MODULE_NR and NC-MD
30230: $MA_ENC_INPUT_NR.
Program Con-
Switch control OFF - ON.
tinuation:
300740
Axis %1 drive %2 measuring system used several times
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The NC has assigned the direct measuring system to a measuring system output which is
already used by another direct measuring system. This error can only occur with the
810D!
Reactions:
- NC not ready.
2-862
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved