Siemens SINUMERIK 840D sl Series Diagnostics Manual page 245

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Definitions:
A block element is required, but the block element memory is empty.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify the block search con-
figuration in machine data 28060 MM_IPO_BUFFER_SIZE (decrease size of IPO buffer if
necessary) or 28070 MM_NUM_BLOCKS_IN_PREP.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15165
Channel %1 block %2 error when translating or interpreting Asup %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Definitions:
At part program start and at start of an ASUB under Reset condition, the relevant data of
all the ASUBs that can be activated at that time are preprocessed:
• PLC ASUBs
• With $MC_PROG_EVENT_MASK configured event-controlled program calls
• ASUB after block search ($MN_SEARCH_RUN_MODE bit 1=1)
• Editable system ASUB ($MN_ASUP_EDITABLE)
If an error occurs (converter or interpreter), alarm 15165 will be output first and then a
converter or interpreter alarm that describes more details of the error. Alarm 15165 will
cause an interpreter stop. A compensation block will not be possible.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15166
Channel %1 user system asup _N_ASUP_SPF not available
Parameters:
%1 = Channel number
Definitions:
By means of the machine data 11610 $MN_ASUP_EDITABLE the function "User-defined
system asup" has been activated. However, the relevant user program could not be found
in the specified search path:
• 1. /_N_CUS_DIR/_N_ASUP_SPF
• 2. /_N_CUS_DIR/_N_ASUP_SPF
The default system asups are used.
Reactions:
- Interface signals are set.
- Alarm display.
Remedy:
Load the user-defined system asup in /_N_CUS_DIR/_N_ASUP_SPF or
/_N_CMA_DIR/_N_ASUP_SPF laden.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15170
Channel %1 block %2 program %3 could not be compiled
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-245

Advertisement

Table of Contents
loading

Table of Contents