Siemens SINUMERIK 840D sl Series Diagnostics Manual page 603

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Program Con-
Internal
tinuation:
112605
Asynchronous subprogram was not executed
Definitions:
The input values could not be correctly processed by the NC.
Reactions:
- Alarm display.
Remedy:
Perform an NCK reset
Program Con-
Internal
tinuation:
112611
NC start not possible:%nDeselect single block
Definitions:
A program was activated with block search while a single block has been active.
Reactions:
- Alarm display.
Remedy:
Deselect the single block.
Program Con-
Internal
tinuation:
112620
Language %1 not installed.
Definitions:
Language not installed.
Reactions:
- Alarm display.
Remedy:
Install language.
Program Con-
Internal
tinuation:
112650
Unknown PLC error
Definitions:
The PLC has announced an error that is unknown in the operator panel.
Reactions:
- NC Start disable in this channel.
- Alarm display.
Remedy:
Press POWER ON, inform Siemens.
Program Con-
Internal
tinuation:
112999
Faulty grafic data. Exit graphic and restart
Definitions:
More data was generated than can be read from the operator panel.
Stop the graphic.
Remedy:
Deselect the graphic and then select it again.
113000
Invalid value - value range: %1
Parameters:
%1 = --
Definitions:
--
Remedy:
--
113001
Incorrect configuration in line %1
Parameters:
%1 = --
Definitions:
--
Remedy:
--
113002
Insufficient access level!
Definitions:
--
Remedy:
--
© Siemens AG, 2005. All rights reserved