Overview of Alarms
Cause:
PROFIBUS is in the data exchange state and clock synchronous operation has been
selected using the parameterizing telegram. Synchronization with the master sign-of-life
(STW2 bits 12-15) could not be completed because the sign-of-life is changing differently
than configured in the Tmapc time grid.
Remedy:
- ensure that the master correctly increments the sign-of-life in the master application clock
cycle.
- check the interconnection of the master sign-of-life (p2045).
201950
<location>PROFIBUS: Clock synchronous operation, synchronization
unsuccessful
Reaction:
OFF1 (NONE)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
Synchronization of the internal clock cycle to the global control telegram has failed. The
internal clock cycle exhibits an unexpected shift.
Remedy:
Siemens-internal
201951
<location>CU DRIVE-CLiQ: Synchronization, application clock cycle
missing
Reaction:
OFF2 (NONE)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
If DRIVE-CLiQ components with different application clock cycle are operated at a DRIVE-
CLiQ port, then this requires synchronization with the control unit.
This synchronization routine was not successful.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry-out a POWER ON (power off/on) for all components.
- upgrade the motor module software.
- upgrade the control unit software.
201952
<location>CU DRIVE-CLiQ: Synchronization of components not
supported
Reaction:
OFF2 (NONE)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The existing system configuration requires at the connected DRIVE-CLiQ components
support the synchronization between the basic clock cycle, DRIVE-CLiQ clock cycle and
the application clock cycle.
However, not all DRIVE-CLiQ components have this functionality.
Fault value (r0949, decimal):
Component number of the first faulted DRIVE-CLiQ component.
Remedy:
Upgrade the firmware of the component specified in the fault value.
Note:
If required, also upgrade additional components in the DRIVE-CLiQ line.
201953
<location>CU DRIVE-CLiQ: Synchronization not completed
Reaction:
NONE
Acknowledge:
NONE
Cause:
After the drive system is powered-up, the synchronization between the basic clock cycle,
DRIVE-CLiQ clock cycle and application clock cycle was started but was not completed
within the selected time (tolerance).
Alarm value (r2124, decimal):
Only for internal Siemens troubleshooting.
Remedy:
Carry-out a POWER ON (power off/on) for all components.
201954
<location>CU DRIVE-CLiQ: Synchronization not successful
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
2-670
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents