Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10947
Channel %1 block %2 curve table %3: contour not continuous
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
The contour in a curve table must be continuous. Incontinuity can occur, for example, as a
result of activating a transformation.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10948
Channel %1 block %2 curve table %3: position jump at end of period
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
A periodic curve table was defined in which the position of the following axis at the end of
the table was different to the position at the start of the table.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10949
Channel %1 block %2 curve table %3: missing master axis motion
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
A slave axis motion has been programmed without a master axis motion.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10950
Channel %1 calculation of arc length function too inaccurate
Parameters:
%1 = Channel number
Definitions:
The calculation of the arc length function could not be performed to the required accuracy.
Reactions:
- Alarm display.
- Warning display.