Siemens SINUMERIK 840D sl Series Diagnostics Manual page 984

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Error Codes of Alarm 300500
Error code
0035H
Error text
Error in software boot section 2
Extension 1
0 or incorrect address
Extension 2
0x60 ;Illegal SERVO reaction on STF handshake
0x61 ;Error during RAM check
0x62 ;Transport checksum does not correspond to that of the SERVO.
Explanation
Errors were detected on loading the drive software. The cause is either faults during the
transfer via the drive bus or a defective control module.
Remedy
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection), replace control module.
Error code
0040H
Error text
Incorrect number of specified current state filters
Extension 1
-
Extension 2
-
Explanation
An illegal number of current setpoint filters (> 4) has been entered.
Remedy
Correct number of current setpoint filters (MD 1200)
Error code
0041H
Error text
Incorrect number of specified rotation speed state filters
Extension 1
-
Extension 2
-
Explanation
An illegal number of speed setpoint filters (> 2) has been entered.
Remedy
Correct the number of speed setpoint filters (MD 1500).
Error code
0044H
Error text
Difference GROBSYNC/FEINSYNC too great.
Extension 1
-
4-984
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents