201040
<location>Save parameter settings and carry-out a POWER ON
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
A parameter was changed in the drive system that means that it is necessary to save the
parameters and run-up again (e.g. p0110).
Remedy:
- save the parameters (p0971/p0977).
- carry-out a POWER ON (power off/on) for all components.
201041
<location>Parameter save necessary
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
Defective or missing files were detected on the CompactFlash Card at run-up.
Fault value (r0949, decimal):
-1: Source file cannot be opened.
-2: Source file cannot be read.
-3: Target directory cannot be set-up.
-4: Target file cannot be set-up/opened.
-5: Target file cannot be written into.
Additional values:
Only for internal Siemens troubleshooting.
Remedy:
- save the parameters (p0977).
- download the project again into the drive unit.
201042
<location>Parameter error during project download
Reaction:
OFF2 (NONE, OFF1, OFF3)
Acknowledge:
IMMEDIATELY
2-624