61369
Channel %1 block %2: Position of corner not clearly definable, check parameter
(_SETV[0...7])
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Define P1 and P2 or P3 and P4 in a way that the intersection of the straights determined
by these points is outside the sections formed by P1 and P2 or P3 and P4.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61370
Channel %1 block %2: _PROTVAL[0] -_PROTVAL[5] do not have any entries
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
Remedy:
Enter values in _PROTVAL[0...5].
61371
Channel %1 block %2: Product of column width and number of columns exceeds
200 characters per line
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
Remedy:
Reduce the column width (_PROTFORM[4]) or number of columns (_PROTVAL[2...5]).
61372
Channel %1 block %2: selected meas.variant requires SPOS-capable spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Change measuring variant or check machine equipment.
61373
Channel %1 block %2: Mono-directional probe requires SPOS-capable spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check machine equipment.
61401
Channel %1 block %2: Probe not switching, traversing path limitation through soft-
ware limit position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961, CYCLE971, CYCLE976,
CYCLE977, CYCLE978, CYCLE998
The position defined by a setpoint value cannot be reached, as the software limit position
has been exceeded.
Remedy:
Check specified setpoint value.
61402
Channel %1 block %2: Probe collision, traversing path limitation through software
limit position