08/2005
No. 8
Explanation
Activate overstore (PI command).
Not allowed if
-
Remedy
-
No. 9
Explanation
Activate overstore (PI command).
Not allowed if
-
Remedy
-
No. 10
Explanation
Perform user interrupt "ASUB" (VDI signal: Digital-analog interface, ASUB interface).
Not allowed if
1. the channel is active due to block search or loading machine data
2. the channel is stopped and the asynchronous subroutine "ASUP_START_MASK"
must be started and the current block cannot be reorganized.
3. digitizing has been selected.
4. reference point approach has not been performed yet.
5. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
− Wait until the block search or loading MD is completed, or abort program (Reset
Remedy
key)
− Activate a block change until the NC block can be reorganized.
− Deactivate digitizing
− Perform reference point approach or ignore this state via the MD
"ASUP_START_MASK".
− Abort program
No. 11
Explanation
Perform "ASUB" user interrupt with rapid retraction (VDI signal: Digital-analog interface).
Not allowed if
See 10
Remedy
-
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition