Siemens SINUMERIK 840D sl Series Diagnostics Manual page 735

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Cause:
Fault detected on the DRIVE-CLiQ component involved. Faulty hardware cannot be
excluded.
Fault value (r0949, hexadecimal):
20: Error in the telegram header.
23: Receive error: The telegram buffer memory contains an error.
42: Send error: The telegram buffer memory contains an error.
43: Send error: The telegram buffer memory contains an error.
Remedy:
- check the DRIVE-CLiQ wiring (interrupted cable, contacts, ...).
- check the electrical cabinet design and cable routing for EMC compliance
- if required, use another DRIVE-CLiQ socket (p9904).
- replace the component involved.
230845
<location>Power module DRIVE-CLiQ: Cyclic data transfer error
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
A DRIVE-CLiQ communications error has occurred between the control unit and the power
module involved.
Fault value (r0949, hexadecimal):
0B: Synchronization error during alternating cyclic data transfer.
Remedy:
Carry-out a POWER ON.
See also: p9916
230850
<location>Power module: Internal software error
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
POWER ON
Cause:
An internal software error in the power module has occurred.
Fault value (r0949, decimal):
1: Background time slice is blocked.
2: Checksum over the code memory is not OK.
3: The synchronization instant of the DSA link coincides with a compare interrupt.
4: Overflow of the software stack.
5: Overflow of the hardware stack (too many nested function calls or interrupts).
6: Program counter contains an invalid program address.
7: In the background, a global interrupt inhibit was detected.
Remedy:
- replace power module.
- if required, upgrade the firmware in the power module.
- contact the Hotline.
230851
<location>CU DRIVE-CLiQ: Sign-of-life missing
Reaction:
OFF2 (NONE, OFF1, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
A DRIVE-CLiQ communications error has occurred between the control unit and the power
module involved. The DRIVE-CLiQ component did not set the sign of life to the control unit.
Fault value (r0949, hexadecimal):
0A: The sign-of-life bit in the receive telegram is not set.
Remedy:
- upgrade the firmware of the component involved.
230860
<location>CU DRIVE-CLiQ: Telegram error
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-735

Advertisement

Table of Contents
loading

Table of Contents