Siemens SINUMERIK 840D sl Series Diagnostics Manual page 231

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
14759
Channel %1 block %2 motion synchronous action and wrong axis type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When there are several feeds, a spark-out time, or a retraction stroke for path motions, at
least one GEO axis must be programmed. If the block also contains synchronous axes
and there are several feeds, the feedrate for the synchronous axes is matched implicitly.
No retraction stroke takes place for synchronous axes. However, after retraction stroke or
spark-out time, the distance-to-go is also deleted in the block for the synchronous axes.
The alarm is no longer used on P3.2.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Program the axis as positioning axis with axial feed, return stroke or spark-out time.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14760
Channel %1 block %2 auxiliary function of a group programmed repeatedly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The M and H functions can be divided up as required over machine data in groups in any
variation. Auxiliary functions are thus put into groups that mutually preclude several indi-
vidual functions of one group. Within one group only one auxiliary function is advisable
and permissible.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Only program one help func-
tion per help function group. (For the group division, see the machine manufacturer's pro-
gramming guide).
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14761
Channel %1 block %2 motion synchronous action: DELDTG function not allowed
with active tool radius compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Rapid delete distance-to-go for synchronous actions is not allowed with DELDTG when
tool radius compensation is active.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Deactivate tool radius compensation before performing rapid delete distance-to-go and
then reselect
or
as of SW 4.3: "Delete distance-to-go without preparation".
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14762
Channel %1 block %2 too many PLC variables programmed
Parameters:
%1 = Channel number
%2 = Block number, label
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-231