Overview of Alarms
%2 = Block number, label
%3 = Axis name
Definitions:
For the indexing axis, the 'Hirth tooth system' function is activated and the override has
been set to 0 or another stop condition (e.g. VDI interface signal) is active. Since it is pos-
sible to stop only on indexing axes, the next possible indexing position is approached.
The alarm is displayed until this position is reached or the stop condition is deactivated.
Reactions:
- Alarm display.
Remedy:
Wait until the next possible indexing position is reached or set override > 0 or deactivate
another stop condition.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
17503
Channel %1 block %2 indexing axis %3 with Hirth tooth system and axis not refer-
enced
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
The 'Hirth tooth system' function is activated for the indexing axis and the axis is to be tra-
versed although it is not referenced.
Reactions:
- Alarm display.
Remedy:
Reference axis.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
17510
Channel %1 block %2 invalid index for indexing axis %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The programmed index for the indexing axis is beyond the position table range.
Example:
Perform an absolute approach of the 56th position in the list allocated via the axis-specific
machine date 30500 INDEX_AX_ASSIGN_POS_TAB with the 1st positioning axis, the
number of positions is e.g. only 40 (MD 10900 INDEX_AX_LENGTH_POS_TAB_1 = 40).
N100 G.. U=CAC (56)
Or, with equidistant distances, the programmed index is smaller or equal 0.
Or, an attempt is made with a MOV movement to travel to a position outside the permitted
area.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Program the indexing axis position in the NC part program in accordance with the length
of the current position table, or add the required value to the position table and adjust the
length of the list.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
17600
Channel %1 block %2 preset on transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
2-310
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005