Definitions:
D number in parameter _KNUM is 0.
The alarm can be triggered by all measuring cycles.
Remedy:
Check parameter _KNUM.
61329
Channel %1 Block %2: Check rotary axis
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No name assigned to the axis number specified under parameter _RA or axis not config-
ured as rotary axis. Alarm is triggered: CYCLE998.
Remedy:
Check MD 20080 or MD 30300.
61330
Channel %1 Block %2: Coordinate rotation active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No measuring possible in the rotated coordinate system. Alarm is triggered: CYCLE972,
CYCLE973, CYCLE974, CYCLE994.
Remedy:
Check the conditions for measuring.
61331
Channel %1 Block %2: Angle too large, change measuring axis
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _STA is too large of the specified metering shaft. Alarm is triggered:
CYCLE998.
Remedy:
Select another metering axis.
61332
Channel %1 Block %2: Modify tool tip position
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool tip is below the measuring probe surface (e.g. for a ring gauge or cube). Alarm is
triggered: CYCLE971, CYLCE972, CYCLE982, E_MT_CAL, E_MT_LEN, E_MT_RAD.
Remedy:
Place the tool above the measuring probe surface.
61333
Channel %1 Block %2: Check calibration facility number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _CALNUM is too large. Alarm is triggered: CYCLE973.
Remedy:
Reduce _CALNUM to a permissible value or increase maximum value _CVAL[2] in
GUD6.
61334
Channel %1 Block %2: Check safety area
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _SZA, _SZO too large or too small. Alarm is triggered: CYCLE977.
Remedy:
Check parameter _SZA, _SZO.
61336
Channel %1 Block %2: Geometry axes do not exist
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
No geometry axes configured. Alarm can be triggered by following measuring cycles: all
measuring cycles.