Siemens SINUMERIK 840D sl Series Diagnostics Manual page 860

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
• Modify MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weak-
ening)
• Modify MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current)
• Modify MD 1119: $MD_SERIES_INDUCTANCE (series reactor inductance)
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors:
• Modify MD 1132: $MD_MOTOR_NOMINAL_VOLTAGE (motor voltage)
• Modify MD 1135: $MD_MOTOR_NOLOAD_VOLTAGE (motor no-load voltage)
• Modify MD 1400: $MD_MOTOR_RATED_SPEED (rated motor speed)
• Modify MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weak-
ening)
• Modify MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current).
• Call the SIEMENS AG, SIMODRIVE Hotline.
Program Con-
Switch control OFF - ON.
tinuation:
300734
Axis %1 drive %2 zero load current less than or equal to zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current) is
less than or equal to zero.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct
MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current).
Program Con-
Switch control OFF - ON.
tinuation:
300735
Axis %1 drive %2 field weakening speed invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field
weakening) is less than or equal to zero.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
2-860
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents