System Reactions on Alarms

Cancel criteria for alarms

5.1
Cancel criteria for alarms
Names
CANCELCLEAR
Effect
The alarm is cleared by pressing the Cancel key in any channel. It is also cleared by the
Start part program key.
− Clear the alarm with the Clear key or with NC START
Names
CLEARHIMSELF
Effect
Self-clearing alarm. The alarm is cleared not by an operator action but explicitly by a
"clearAlarm" in programmed the NCK source code.
− Alarm display disappears with alarm cause. No further operator action necessary.
Names
NCSTARTCLEAR
Effect
The alarm is cleared by starting a program in the channel, in which the alarm occurred.
The alarm is also cleared by an NC reset.
− Clear the alarm with NC START or the RESET key and continue the program.
Names
POWERONCLEAR
Effect
The alarm is canceled by turning off / turning on the control system (POWER ON).
− Switch the control OFF - ON.
Names
RESETCLEAR
Effect
The alarm is cleared by pressing the Reset key in the channel in which the alarm
occurred.
− Clear alarm with the RESET key. Restart part program.
Names
BAGRESETCLEAR
Effect
The alarm is cleared by a "BAGRESETCLEAR" command or by carrying out a reset in
all channels of this mode group.
− Press the RESET key to clear the alarm in all channels of this mode group. Restart
part program.
Names
NCKRESETCLEAR
Effect
The alarm is cleared by an "NCKRESETCLEAR" command or by carrying out a reset in
all channels.
− Clear alarm in all channels with the RESET key. Restart part program.
Names
NOCLEAR
Effect
The clear information is only required for the internal pseudo alarm number
EXBSAL_NOMOREALARMS.
5-990