Overview of Alarms
Remedy:
Check and, if necessary, change the basic settings.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61014
Channel %1 Block %2: Return plane exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE72.
Remedy:
Check parameter RTP.
61015
Channel %1 Block %2: Contour is not defined
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61016
Channel %1 block %2: System frame for cycles missing
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
All measuring cycles can trigger this alarm.
Remedy:
Set MD 28082: MM_SYSTEM_FRAME_MASK, Bit 5=1.
61017
Channel %1 block %2: function %4 not present in NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61018
Channel %1 block %2: function %4 not executable with NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
2-440