Siemens SINUMERIK 840D sl Series Diagnostics Manual page 254

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15810
Channel %1 block %2 wrong array dimension for CONTPRON/CONTDCON
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The number of columns for the array created for CONTPRON/CONTDCON does not con-
form to the current programming guide.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15900
Channel %1 block %2 touch probe not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure with deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAS
(measure with deletion of distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAS=2 G01 X100 Y200 Z300 F1000
Probe 2 with deletion of distance-to-go
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Include a probe number within the limits given above in the keyword MEAS=... This must
correspond to the hardware connection of the probe.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
15910
Channel %1 block %2 touch probe not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Measure without deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAW
(measure without distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
2-254
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005