Overview of Alarms
Definitions:
The rotation of orientation (3rd degree of freedom of orientation for 6-axis transforma-
tions) has been programmed with G code ORIROTC active. This is not possible, as the
rotation of orientation is oriented relatively to the path tangent when ORIROTC is active.
With ORIROTC, it is only possible to program the angle of rotation THETA that indicates
the angle
of the rotation vector to the path tangent.
Reactions:
- Correction block is reorganized.
- Interpreter stop
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14129
Channel %1 block %2 orientation angles and orientation vector components pro-
grammed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An orientation angle and components of an orientation vector were programmed at the
same time.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14130
Channel %1 block %2 too many initialization values given
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
On assigning an array by means of SET, more initialization values than existing array ele-
ments have been specified in the program run.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Reduce the number of initialization values.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14131
Channel %1 block %2 orientation axes and lead/tilt angles programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An orientation angle and a leading or sideways angle were programmed at the same time.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
2-198