Siemens SINUMERIK 840D sl Series Diagnostics Manual page 209

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In specifying the endpoints in a traversing block with G00, G01, G02 or G03 in polar coor-
dinates, the value range of the polar angle programmed under the keyword AP=... has
been exceeded. It covers the range from -360 to +360 degrees with a resolution of 0.001
degrees.
Definition of terms:
• Specification of end of block point with polar angle and polar radius, referring to the cur-
rent pole (preparatory functions: G00/G01/G02/G03).
• New definition of the pole with polar angle and pole radius, referring to the reference
point selected with the G function. G110 ... referred to the last programmed point in the
plane, G111 ... referred to the zero point of the current workpiece coordinate system
(WCS), G112 ... referred to the last pole.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Correct NC part program. The permissible input range for the polar angle is between the
values -360 degrees and +360 degrees with a resolution of 0.001 degrees.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14250
Channel %1 block %2 negative pole radius
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In redefining the pole with G110, G111 or G112 in polar coordinates, the pole radius
specified under keyword RP=... is negative. Only positive absolute values are permitted.
Definition of terms:
• Specification of end of block point with polar angle and polar radius, referring to the cur-
rent pole (preparatory functions: G00/G01/G02/G03).
• New definition of the pole with polar angle and pole radius, referring to the reference
point selected with the G function. G110 ... last programmed point in the plane, G111 ...
zero point of the current work, G112 ... last pole
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the NC part program. Permissible inputs for the pole radius are only positive,
absolute values that specify the distance between the reference point and the new pole.
(The direction is defined with the pole angle AP=...).
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14260
Channel %1 block %2 pole angle too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In redefining the pole with G110, G111 or G112 in polar coordinates, the value range of
the pole angle specified under keyword AP=... has been exceeded. It covers the range
from -360 to +360 degrees with a resolution of 0.001 degrees.
Definition of terms:
• Specification of end of block point with polar angle and polar radius, referring to the cur-
rent pole (preparatory functions: G00/G01/G02/G03).
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms