Siemens SINUMERIK 840D sl Series Diagnostics Manual page 879

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
(make the value in MD 1465: $MD_SWITCH_SPEED_MSD_AM less than the value in
MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
300772
Axis %1 drive %2 asynchronous mode: speed control gain too high
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1451: $MD_SPEEDCTRL_GAIN_1_AM (proportional gain of AM speed
controller) is too high.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department. The current set in MD1019:
$MD_SPEEDCTRL_GAIN_1_AM (proportional gain of AM speed controller).
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
300773
Axis %1 drive %2 asynchronous mode: feedforward control structure not possible
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
In asynchronous mode (select by MD 1465 < MD 1146) a feedforward control structure
(MD 1004, bit 0 = 1) is not possible.
• Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM)
• Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed)
• Modify MD 1004: $MD_CTRL_CONFIG (configuration structure)
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
Rectify the error in the entry for the feedforward control structure MD 1004 or by deselect-
ing the asynchronous mode MD 1465 > MD 1146.
• Modify MD 1004: $MD_CTRL_CONFIG (configuration structure)
• Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM)
• Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed)
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition