Appendix 1.16.3 Canceling The Position Switch - Mitsubishi Electric C70 Setup Manual

Hide thumbs Also See for C70:
Table of Contents

Advertisement

For the rotary axis:
Setting of dog1 and dog2
dog1 < dog2
dog1 > dog2
dog1<=0 and
360<=dog2

Appendix 1.16.3 Canceling the Position Switch

To cancel the position switch‚ enter the number (#75*1) of the position switch to be canceled in # ( ) of the setting
area‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis name for the specified position
switch‚ thus invalidating the position switch. The data specified for <dog1> and <dog2> are still stored in memory.
To validate the position switch again‚ therefore‚ it is enough to specify the axis name only.
Positions of dog1 and dog2
dog2
dog1
(Example)
dog1 = 30.000
dog2 = 330.000
dog1
dog2
(Example)
dog1 = - 30.000
dog2 = 30.000
dog1
dog2
(Example)
dog1 = 330.000
dog2 = 30.000
dog2 dog1
(Example)
dog1 = 30.000
dog2 = 390.000
Appendix 1.16 Position Switch Function Outline
Description
A signal is output between dog1 and
dog2.
A signal is also output when dog1 is
negative.
A signal is output between dog1 and
dog2.
When the range of dog1 and dog2
include 0 to 360 degrees, a signal is
output whenever and wherever the
machine reaches.
C70 Setup Manual
415