MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#13111】 SP111
Not used. Set to "0".
【#13112】 SP112 IFF OMR-FF current feed forward gain
Set the current feed forward rate in OMR-FF control.
The standard setting is "10000".
Setting value of 0 is equal to "10000(100%)" setting.
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 32767 (0.01%)
【#13113】 SP113 OPLP Current command value for open loop
Set the current command value for when the open loop control is enabled.
When "0" is set, the state will be the same as when "50" is set.
When not using, set to "0".
The open loop control is enabled when "SP018/bit1" is set to "1".
---Setting range---
0 to 999 (Short-time rated %)
【#13114】 SP114 MKT Coil changeover gate cutoff timer
Set the time required to cut off the gate when turning OFF/ON the coil switch contactor.
The value should be longer than the coil switch contactor's OFF/ON time.
The standard setting is "150".
---Setting range---
0 to 3500 (ms)
【#13115】 SP115 MKT2 Coil changeover current limit timer
Set the time required to limit the current immediately after the coil switch contactor ON/OFF is
completed and the gate is turned ON.
The standard setting is "250".
---Setting range---
0 to 3500 (ms)
【#13116】 SP116 MKIL Coil changeover current limit value
Set the time required to limit the current immediately after the coil switch contactor ON/OFF is
completed and the gate is turned ON.
The standard setting is "120".
---Setting range---
0 to 999 (Short-time rated %)
【#13117】 SP117 SETM Excessive speed deviation timer
Set the time to detect the speed excessive error alarm.
Set the time required to the machine.
The standard setting is "12".
---Setting range---
0 to 60 (s)
【#13118(PR)】 SP118 MSFT Magnetic pole shift amount
Set the magnetic pole shift amount of IPM spindle motor.
During DC excitation of the initial setup: Set the same value displayed in the "AFLT gain" on the NC
monitor screen in SP225/bit4=1.
When not using, set to "0".
---Setting range---
-18000 to 18000 (electrical angle 0.01°)
324