Appendix 1.11 PLC Parameters

【#6000 - 6015】 T000-T015 10ms adding timer <10ms>
Set the time for the timer used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit0" in the following "[BIT SELECT]" is set
---Setting range---
0 to 32767 ( x 10ms)
【#6016 - 6095】 T016-T095 100ms adding timer <100ms>
Set the time for the timer used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit0" in the following "[BIT SELECT]" is set
---Setting range---
0 to 32767 ( x 100ms)
【#6096 - 6103】 T096-T103 100ms cumulative timer <100msINC>
Set the time for the timer used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit0" in the following "[BIT SELECT]" is set
---Setting range---
0 to 32767 ( x 100ms)
【#6200 - 6223】 C000-C023 Counter
Set the time for the counter used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit1" in the following "[BIT SELECT]" is set
---Setting range---
0 to 32767
【#6301 - 6348】 R4500,R4501 - R4594,R4595 PLC constant
Set the value to be set in the data type R register used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this parameter is
displayed. the screen will not change.Enter a different screen once. and then select this screen
again.
Note that some parameters have limited uses.
---Setting range---
-99999999 to 99999999
【#6401,6402 - 6495,6496】 R4600-Low,R4600-High - R4647-Low,R4647-High Bit selection
This is the bit type parameter used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this parameter is
displayed, the screen will not change. Enter a different screen once, and then select this screen
again.
Note that some parameters have limited uses.
0 : OFF
1 : ON
【#6449】
bit7: Control unit overheat detected
Designate whether to detect the control unit overheat alarm or not.
0 : Detect
1 : Not detect
to "0".
to "0".
to "0".
to "0".
C70 Setup Manual
Appendix 1.11 PLC Parameters
369