【#22011】 bscmp- Offset compensation position
Set the coordinate position to compensate by the offset amount on the machine basic coordinate
system.
(Note) Either #22011 or #22012 can be negative.
---Setting range---
-99999.999 to 99999.999
【#22012】 bscmp+ Max. compensation position
Set the coordinate position to compensate by the maximum offset amount on the machine basic
coordinate system.
(Note) Either #22011 or #22012 can be negative.
---Setting range---
-99999.999 to 99999.999
【#22013】 synwd
Not used. Set to "0".
【#22014(PR)】 Mastno Multi-secondary-axis sync primary axis number
Set the axis No. of the primary axis to the each secondary axis to set multiple-secondary-axis
synchronous control.
The axis number is a serial number of NC axis that regards the 1st axis of the 1st part system as "1".
Set to "0" when not using.
---Setting range---
0 to 16
Appendix 1.4 Axis Specifications Parameters