【#12816+10(n-1)】 justn Operation parameter group n Set position output width
Set the tolerable value at which "set position reached" (JST) or "automatic set position reached"
(JSTA) signal is output when "operation parameter group n" is selected.
"Set position reached" (JST) indicates that the machine position is at any station.
During automatic operation, "automatic set position reached" (JSTA) is also output under the same
condition.
These signals will turn OFF when the machine position moves away from the station over this value.
---Setting range---
0.000 to 99999.999( ° or mm)
【#12817+10(n-1)】 nearn Operation parameter group n Near set position output width
Set the tolerable value at which "near set position" (NEAR) signal is output when "operation
parameter group n" is selected.
"Near set position" (NEAR) indicates that the machine position is near any station position.
This value is generally set wider than the set position output width. During operations, this is related
to the special commands when the station selection is set to "0".
---Setting range---
0.000 to 99999.999(° or mm)
【#12818+10(n-1)(PR)】 smgstn Operation parameter group n Acceleration/Deceleration type
Select the acceleration/deceleration type when "operation parameter group n" is selected.
1: Linear acceleration/deceleration
F: S-pattern acceleration/deceleration
【#12850】 stpos2 Station 2 coordinate
Set the station 2 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12851】 stpos3 Station 3 coordinate
Set the station 3 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12852】 stpos4 Station 4 coordinate
Set the station 4 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12853】 stpos5 Station 5 coordinate
Set the station 5 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12854】 stpos6 Station 6 coordinate
Set the station 6 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)