【#1065】 JOG_H JOG response type
Set the JOG responsiveness type.
0: Conventional specification
1: Type 1
2: Type 2
3: Type 3
4: Type 4
---Setting range---
0 to 4
【#1066】 JOG_HP Select JOG activation (+) device
Set the device No. to input +JOG activation signal.
The device type is specified by "#1071 JOG_D".
The effective setting range varies depending on the device type.
A value specified outside of the effective range is invalid.
---Setting range---
X: 0000 to 02FF (hexadecimal)
M: 0000 to 8191 (decimal)
【#1067】 JOG_HN Select JOG activation (-) device
Set the device No. to input -JOG activation signal.
The device type is specified by "#1071 JOG_D".
The effective setting range varies depending on the device type.
A value specified outside of the effective range is invalid.
---Setting range---
X: 0000 to 02FF (hexadecimal)
M: 0000 to 8191 (decimal)
【#1068(PR)】 slavno Secondary axis number
Set the axis number of the secondary axis in synchronous control.
The axis number is an NC number excluding the spindle and PLC axis.
Two or more secondary axes cannot be set for one primary axis.
This parameter cannot be set for a secondary axis.
When using the multi-part system, the relation of the primary axis and secondary axis cannot extend
over part systems.
0: No secondary axis
1 to 8: First to eighth axis
【#1069】 no_dsp Axis with no counter display
Select whether to display the axis counter or not.
This setting is enabled on the counter display screen (relative position counter, etc.).
0: Display
1: Not display
【#1070】 axoff Axis removal
Select whether to enable or disable axis removal control.
0: Disable
1: Enable
JOG is started or stopped by a signal via ladder without reference to an external signal input.
JOG is started or stopped by an external signal.
JOG is started or stopped by logical AND of an external signal and a signal via ladder.
JOG is started when a signal via ladder rises. It is stopped when an external signal and a signal
via ladder fall.
Reference position return mode:
JOG is started or stopped by a signal via ladder without reference to an external input signal
(conventional specification).
Non-reference position return mode:
JOG is started or stopped by logical AND of an external signal and a signal via ladder (type 2).
Appendix 1.3 Base Specifications Parameters
C70 Setup Manual
183