Mitsubishi Electric C70 Setup Manual page 207

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#1129】 PwrVCl Clear variables by power-ON
Select how to handle the common variables when the power is turned ON.
0: The common variables are in the same state as before turning the power OFF.
1: The following common variables will be cleared when the power is turned ON:
【#1130】 set_t Display selected tool number
Select the tool command value display on the POSITION screen.
0: Display T-modal value of program command
1: Display Tool No. sent from PLC
【#1131】 Fldcc
Not used. Set to "0".
【#1132】 CRT
Not used. Set to "0".
【#1133】 ofsmem Select how to set up tool wear compensation screen
Select whether to display the # number stored at the previous setup, when selecting the tool
compensation screen.
0: Not display the # number when selecting the screen.
1: Display the stored # number when selecting the screen.
【#1134】 LCDneg
Not used. Set to "0".
【#1135】 unt_nm Unit name
Set the unit name.
Set with 4 or less characters consisting of both alphabets and numbers.
If "0" is set, the unit name won't be displayed.
---Setting range---
4 or less characters consisting of both alphabets and numbers
【#1138】 Pnosel Select screen by parameter number
Select whether to enable the function to select a screen by specifying a parameter number.
0: Disable
1: Enable
【#1139】 edtype Edit type selection
Select an edit type.
0: Screen edit type (M50 or equivalent operation)
1: Screen edit type
2: Word edit type
【#1140】 Mn100 M code number
Set the first number of M code that corresponds to the setup Nos. from 100 to 199.
---Setting range-
0 to 99999999
【#1141】 Mn200 M code number
Set the first number of M code that corresponds to the setup Nos. from 200 to 299.
---Setting range---
0 to 99999999
190
#100 to #149 when 100 sets of variables are provided.
#100 to #199 when 200 sets or more of variables are provided.
(The screen of EDIT or MDI is changed automatically according to the selected operation
mode.)
(The screen of EDIT or MDI is changed automatically according to the selected operation
mode.)

Advertisement

Table of Contents
loading

Table of Contents