Appendix 1 Explanation of Parameters
【#3015】 stap 3 Synchronous tapping 1st step rotation speed (Gear: 10)
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step
acceleration/deceleration control when gear 10 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
stap3(#3015) to stapt3(#3019).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/
deceleration control is executed with the same inclination as the 1st step for the rotation speed of
stap3 or higher.
---Setting range---
0 to 99999 (r/min)
【#3016】 stap 4 Synchronous tapping 1st step rotation speed (Gear: 11)
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step
acceleration/deceleration control when gear 11 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
stap4(#3016) to stapt4(#3020).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/
deceleration control is executed with the same inclination as the 1st step for the rotation speed of
stap4 or higher.
---Setting range---
0 to 99999 (r/min)
【#3017】 stapt 1 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 00 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
【#3018】 stapt 2 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 01)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 01 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
【#3019】 stapt 3 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 10 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
【#3020】 stapt 4 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 11 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
【#3021】
Not used. Set to "0".