MITSUBISHI CNC
Appendix 2 Explanation of Alarms
The Flow when the "Y03 AMP. UNEQUIPPED" occurs.
"Y03 AMP. UNEQUIPPED"
Is the drive unit
power OFF ?
no
Any axis
not being connected
to the drive unit ?
no
Values of
"#1002 axisno" or "#1039 spinno"
too large?
no
Drive unit's rotary switch
settings overlapped?
no
A
554
yes
yes
yes
no
yes
Set rotary switches so as not
to be overlapped.
Turn the drive unit power and
NC power ON again.
Is the error removed?
no
yes
Continued on next page
Set the target axis' "#2018 no_srv"
to "1" or "#3024 sout" to "0".
Turn the NC power ON again.
Is the error removed?
no
Decrease the setting value.
Turn the drive unit and NC
power ON again.
Is the error removed?
yes
Turn the drive unit power ON.
Turn the NC power ON again.
Is the error removed?
no
yes
yes
B