Appendix 1.3 Base Specifications Parameters
The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF and ON to enable
the parameter settings.
【#1001(PR)】 SYS_ON System validation setup
Select the existence of PLC axes and part systems.
0: Not exist
1: Exist
【#1002(PR)】 axisno Number of axes
Set the number of control axes and PLC axes.
Up to 16 axes, including the number of spindles (in "#1039 spinno"), can be set.
Control axis: 0 to 8
PLC axis: 0 to 8
When set to "0", the number of control axes in the part system will be "0". "1" or more control axes
must be set for the 1st part system.
【#1003(PR)】 iunit Input setup unit
Select the input setting increment for each part system and PLC axis.
The parameter setting increment will follow this specification.
B : 1μm
C : 0.1μm
【#1013(PR)】 axname Axis name
Set each axis' name with an alphabetic character.
Use the characters X, Y, Z, U, V, W, A, B or C.
(Note 1) Do not set the same name twice in one part system.
(Note 2) The PLC name does not need to be set. (Numbers 1 and 2 are shown as the axis names.)
---Setting range---
X,Y,Z,U,V,W,A,B,C
【#1014(PR)】 incax Increment command axis name
Set the axis name when commanding an incremental value for the axis travel amount.
Available alphabets are the same as in "#1013 axname".
(Note 1) Set an alphabet that is different from that of "#1013 axname".
(Note 2) Setting is not required if absolute/incremental specification with axis names is not
---Setting range---
X, Y, Z, U, V, W, A, B, C
【#1015(PR)】 cunit Program command unit
Set the minimum increment of program travel command.
When set to "0", it becomes 0.001mm(1μm).
cunit Travel amount for travel command 1
1: 0.0001 mm (0.1μm)
10: 0.001 mm (1μm)
100: 0.01 mm (10μm)
1000: 0.1 mm (100μm)
10000: 1.0 mm
If there is a decimal point in travel command, the decimal point position will be handled as 1mm
regardless of this setting.
【#1016(PR)】 iout Inch output
Select the unit system used for setting mechanical values (ball screw pitch and position detection
unit).
0 : Metric system
1 : Inch system
The same name which is used in another part system can be set.
performed ("#1076 Abslnc" = "0").
Appendix 1.3 Base Specifications Parameters
C70 Setup Manual
177