Appendix 1 Explanation of Parameters
【#2003(PR)】 smgst Acceleration and deceleration modes
Set acceleration and deceleration control modes.
Set value is in hexadecimal.
HEX
bit
HEX-1 Rapid traverse acceleration/deceleration type
0(bit3,2,1,0 = 0000) : Step
1(bit3,2,1,0 = 0001) : Linear acceleration/deceleration
2(bit3,2,1,0 = 0010) : Prim ary delay
8(bit3,2,1,0 = 1000) : Exponential acceleration and linear deceleration
F(bit3,2,1,0 = 1111) : Soft acceleration/deceleration
(Note) R1 > R3 when both R1 and R3 contain 1.
HEX-2 Cutting feed acceleration/deceleration type
0(bit7,6,5,4 = 0000) : Step
1(bit7,6,5,4 = 0001) : Linear acceleration/deceleration
2(bit7,6,5,4 = 0010) : Prim ary delay
8(bit7,6,5,4 = 1000) : Exponential acceleration and linear deceleration
F(bit7,6,5,4 = 1111) : Soft acceleration/deceleration
HEX-3 Stroke end stop types
0(bit9,8 = 00) : Linear deceleration (Decelerates at G0t1)
1(bit9,8 = 01) : Linear deceleration (Decelerates at 2×G0t1)
2(bit9,8 = 10) : Position loop step stop
3(bit9,8 = 11) : Position loop step stop
Speed
(Note) OT1(bit8) is valid under the following conditions (valid for dog type zero point return):
HEX-4
Not used. Set to "0".
232
4
F
E
D
C
B
     Stroke end stop types
G0t1
- Stop type: Linear deceleration
- Acceleration/Deceleration mode: Exponential acceleration and Linear deceleration
3
2
A
9
8
7
6
OT2 OT1 C3
C2
C1
Cutting feed 
acceleration
/deceleration type
2 x G0t1 (OT1=1,OT2=0)
G0t1 (OT1=OT2=0)
Stroke end signal
1
5
4
3
2
1
0
L
R3
R2
R1
LR
Rapid traverse 
acceleration
/deceleration type

Advertisement