【#7052】 M[06] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7053】 M[06] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
【#7061】 M[07] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
【#7062】 M[07] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7063】 M[07] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
【#7071】 M[08] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
【#7072】 M[08] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7073】 M[08] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999