5.3 Setting Multi-CPU Parameters to PLC CPU

When one PLC CPU and two CNC CPUs are mounted, set "3" for "No. of PLC" in the "Multiple CPU settings" dialog box.
The point of PLC No.1 varies according to the value to be set for the parameter "#26742 G Device TOP number" of
CPU#3 in "5.4 Setting Multi-CPU Parameters to CNC CPU".
(1) When setting the control signal of CPU#3 to G13072
Set "6" for the PLC No.1's "point".
(2) When setting the control signal of CPU#3 to G14000
This enables to start the CNC control signal from a round number.
Set "7" for the PLC No.1's "point".
5.3 Setting Multi-CPU Parameters to PLC CPU
C70 Setup Manual
93