【#7001】 M[01] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
【#7002】 M[01] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7003】 M[01] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
【#7011】 M[02] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
【#7012】 M[02] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7013】 M[02] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
【#7021】 M[03] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
【#7022】 M[03] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call