9.2.2.1 Stored Stroke Limit I

This is a stroke limit function used by the machine tool builder. The boundary is set with the parameters ("#2013 OT -
(Soft limit I -)" and "#2014 OT + (Soft limit I +)"). The outside of the set boundary is the prohibited range.
When used with the stored stroke limit II function, the confined range designated by the two functions becomes the
moveable range.
(Note 1) This function will be invalid if the same value excluding "0" is set for both "#2013 OT -" and "#2014 OT +".
(Note 2) When using the peripheral axis, inside of the specified range will be prohibited if the "#2013 OT -" value is
larger than that of "#2014 OT +".
2
(A)
: Moveable range
: Prohibited range
(A): Set value for (-) side
(B): Set value for (+) side
Point 1: "#2014 OT+ (Soft limit I +)" and
Point 2: "#2013 OT+ (Soft limit I +)"
are set with the coordinate value of the basic machine coordinate system.
C70 Setup Manual
9.2 Storeed Stroke Limit (S/W OT)
1
(B)
147