【#1027】 base_J Base axis J
Set the names of the basic axes that compose the plane.
Set the axis name set in "#1013 axname".
If all three items ("base_I", "base_J" and "base_K") do not need to be set, such as for 2-axis
specifications, input "0", and the parameter will be blank.
Normally, when X, Y and Z are specified respectively for base_l, _J, _K, the following relation will be
established:
G17: X-Y
G18: Z-X
G19: Y-Z
Specify the desired axis name to set an axis address other than above.
---Setting range---
Axis names such as X, Y or Z
【#1028】 base_K Base axis K
Set the names of the basic axes that compose the plane.
Set the axis name set in "#1013 axname".
If all three items ("base_I", "base_J" and "base_K") do not need to be set, such as for 2-axis
specifications, input "0", and the parameter will be blank.
Normally, when X, Y and Z are specified respectively for base_l, _J, _K, the following relation will be
established:
G17: X-Y
G18: Z-X
G19: Y-Z
Specify the desired axis name to set an axis address other than above.
---Setting range---
Axis names such as X, Y or Z
【#1029】 aux_I Flat axis I
Set the axis name when there is an axis parallel to "#1026 base_I".
---Setting range---
Axis names such as X, Y or Z
【#1030】 aux_J Flat axis J
Set the axis name when there is an axis parallel to "#1027 base_J".
---Setting range---
Axis names such as X, Y or Z
【#1031】 aux_K Flat axis K
Set the axis name when there is an axis parallel to "#1028 base_K".
---Setting range---
Axis names such as X, Y or Z