MITSUBISHI CNC
2 GOT Initial Setup
(3) The "System Environment" dialog box now displays "Communication Settings". Confirm "Use Communication
Settings" is checked, and select the following items of the extended I/F setting from among the pull-down menu.
Extend I/F-1 1st
CH No.: 1
Driver: Ethernet(MELSEC), Q17nNC, CRnD-700
Then click "Detail Setting...".
(Note)
Select "Extend I/F-2(1st)" when the Ethernet communication unit is mounted on the GOT rear slot IF-2.
(4) Set the following values in the "Communication Detail Settings" dialog box.
GOT NET No.: 1
GOT PC No.: 1
GOT IP Address: GOT's own IP address (Example: 192.168.1.1)
After setting, click "OK" to confirm the setting values.