Mitsubishi Electric C70 Setup Manual page 381

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#29079(PR)】 Master Func. IO Addr. Area PLC side Device
Set the device to store the following data:
The data which stores the head address and size (in word form) of the master function receive and
transmit data used by each slave node.
00(HEX): Input data head address of the 1st slave node
01(HEX): Input data size (word count) of the 1st slave node
02(HEX): Output data head address of the 1st slave node
03(HEX): Output data size (word count) of the 1st slave node
04(HEX): Input data head address of the 2nd slave node
FB(HEX): Output data size (word count) of the 63rd slave node
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29080(PR)】 Master Func. Receive Data Module side Transfer Cont.
Set a read word count of the data received from each slave node.
The standard setting is "256".
---Setting range---
1 to 256
【#29081(PR)】 Master Func. Receive Data PLC side Device
Set the device to read the data received from each slave node.
<Data configuration>
The data is aligned at the word boundaries of the slave nodes before stored.
Double-word data is stored in the order of lower word first and higher word next.
If there is an odd number of byte input modules, one byte of empty area will be inserted for alignment
at the word boundary. Bit input modules are treated in the same way as the byte input modules.
<Example>
Slave node configuration
---Setting range---
Within the number of device points set in the PC parameter's device setting.
364
Master function I/O address area read device
:
:
Master function receive data read word count
Master function receive data read device
1st node -
2nd node -
3rd node -
Receive data buffer
Offset from head address
0000
H
0001
H
0002
H
0003
H
0004
H
0005
H
0006
H
0007
H
0008
H
0009
H
Number of byte input modules = 3
Number of word input modules = 2
Number of double-word input modules = 2
Number of byte input modules = 1
Number of byte input modules = 1
2nd byte module
1st byte module
Empty
3rd byte module
1st word module
2nd word module
Lower word of the
1st double-word module
Higher word of the
1st double-word module
Lower word of the
2nd double-word module
Higher word of the
2nd double-word module
Empty
1st byte module
Empty
1st byte module
If there is an odd number
of byte input modules,
one byte of empty area
will be inserted.
Input data of the 1st node
Input data of the 2nd node
Input data of the 3rd node

Advertisement