Appendix 1 Explanation of Parameters
【#29030(PR)】 Cyclic Data:Area2 Local Node Area Module side Buffer off.
Cyclic data: Area2 Local node area Module side buffer offset
Set the head offset of the buffer for setting the data which is transferred by the local node to the
cyclic data area 2 (word area).
The standard setting is "0".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the transfer size is
---Setting range---
0 to 8192
【#29031(PR)】 Cyclic Data:Area2 Local Node Area PLC side Device
Cyclic data: Area2 Local node area CPU side device
Set the internal device to store the data transferred by the local node to cyclic data area 2 (word
area).
---Setting range---
CPU-side device
【#29032(PR)】 Cyclic Data:Area2 Other Node Area Module side Transfer Cont.
Cyclic data: Area2 Other node area Module side transfer word count
Set the word count of the data used for reading the other node data in cyclic data area 2 (word area).
The standard setting is "8192".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the transfer size is
---Setting range---
1 to 8192
【#29033(PR)】 Cyclic Data:Area2 Other Node Area Module side Buffer off.
Cyclic data: Area2 Other node area Module side buffer offset
Set the head offset of the buffer used for reading the other node data in cyclic data area 2 (word
area).
The standard setting is "0".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the transfer size is
---Setting range---
0 to 8192
【#29034(PR)】 Cyclic Data:Area2 Other Node Area PLC side Device
Cyclic data: Area2 Other node area CPU side device
Set the internal device used for reading the other node data in cyclic data area 2 (word area).
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29035(PR)】 Cyclic Data:Area2 Other Node Area Module side Transfer Cont.
Cyclic data: Area2 Other node area Module side transfer word count
Set the word count of the data used for reading the other node data in cyclic data area 2 (word area).
The standard setting is "8192".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the transfer size is
---Setting range---
1 to 8192