MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#29019(PR)】 Status Data:Word Message Inform.
Status data: Message information area
Set a device to store the following data:
<1st word: Message information area>
Response message classification:
Stores the message classification (status) of message transmission using message receive area.
00(HEX): Normal message response or request message
01(HEX): Error message response
02(HEX): Not supported
<2nd word: Message information area>
Virtual address space data size:
Stores data size when using virtual address space in the transmission of message using message
receive area.
Setting range: 0001 to FFFF (HEX)
Setting "0" makes the virtual address space unused.
<3rd, 4th word: Message information area>
Virtual address space first address
Stores the first address (32 bits) when using virtual address space in the transmission of message
using message receive area.
Setting range: 0 to FFFFFFFF (HEX)
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29020(PR)】 Cyclic Data:Area1 Local Node Area Module side Transfer Cont.
Cyclic data: Area1 Local node area Module side transfer word count
Set the word count of the data which is transferred by the local node to cyclic data area 1 (bit area).
The standard setting is "512".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size is added.
---Setting range---
1 to 512
【#29021(PR)】 Cyclic Data:Area1 Local Node Area Module side Buffer off.
Cyclic data: Area1 Local node area Module side buffer offset
Set the head offset of the buffer for setting the data which is transferred by the local node to the
cyclic data area 1 (bit area).
The standard setting is "0".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size is added.
---Setting range---
0 to 512
【#29022(PR)】 Cyclic Data:Area1 Local Node Area PLC side Device
Cyclic data: Area1 Local node area CPU side device
Set the internal device to store the data transferred by the local node to the cyclic data area 1 (bit
area).
---Setting range---
CPU-side device
【#29023(PR)】 Cyclic Data:Area1 Other Node Area Module side Transfer Cont.
Cyclic data: Area1 Other node area Module side transfer word count
Set the word count of the data used for reading the other node data in cyclic data area1 (bit area).
The standard setting is "512".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size is added.
---Setting range---
1 to 512
352